Spark Services Subpanel Installation
Subpanel Installation in California
Feed a garage, a shop, an addition or an accessory unit.
The short version
- A subpanel keeps ground and neutral separate, unlike the main.
- Detached buildings need a ground rod of their own.
- Four wires go out to a separate building, not three.
- Accessory dwelling units almost always need one.
When a subpanel makes sense
When a part of the property needs several circuits, feeding one larger cable out to a small panel beats running four or five separate circuits. A garage shop, a pool area, an addition or an accessory dwelling unit all fit that shape.
It also puts breakers where the work is, so a tripped circuit in the shop does not mean a walk back to the house.
The rule people get wrong
In the main panel the neutral bar and the ground bar are bonded together. In a subpanel they must be separate, with the neutrals floating on their own insulated bar. A bonded subpanel puts current on the ground wire and on anything metal that touches it.
This is the single most common error in work done without a permit, and it is the first thing an inspector looks for.
Feeding a detached building
A separate structure gets four conductors, two hot, one neutral and one ground, in conduit rated for burial. It also needs its own ground rod or rods, and a way to shut off power at the building.
Trenching depth depends on the conduit used and the local rules. Get the depth right the first time, because the inspector looks before it is covered.